D285DH Cabezal humo conducto, 2/4 cabl., 12/24V
  • Commercial or residential applications
  • Two-wire or four-wire application, depending on base
  • Chamber Check rapid-flash LED Automatic Trouble Indication reports contaminated chamber
  • Flashing LED power indicator
  • Steady-On LED alarm indicator
  • Modular design
 
 
D340 Family two‑wire duct smoke detector housings
  • For 1 ft. (30.5 cm) to 10 ft. (3 m) ducts with air velocity between 300 ft./min. to 4000 ft./min. (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
 
 
D341 Family four‑wire duct smoke detector housings
  • For 1 ft. (30.5 cm) to 10 ft. (3 m) ducts with air velocity between 300 ft./min. to 4000 ft./min. (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
 
 
D342 Family four‑wire duct smoke detector housings
  • For 1 ft. (30.5cm) to 10 ft. (3 m) ducts with air velocity between 300 ft./min. to 4000 ft./min. (1.52 m/s to 20.3 m/s)
  • Easy duct tube installation through the housing cuts installation time
  • Detector test and reset without removing covers
  • Clear cover allows quick visual inspection
  • Tube filters, dust immune smoke detector, and easy disassembly for cleaning reduce maintenance time and cost
 
 
D282A-DH Cabezal detector repuesto, conducto, 24V
  • 24 VDC replacement detector head for D300A and D300A‑HV Conventional Duct Detector Housings
  • Easy head removal for cleaning and servicing
  • Flashing LED power on indicator
 
 
D300A Detector humo, conducto 24/115V
  • Conventional duct detector (D300A)
  • For use with Bosch D7022 and D7024 Conventional Fire Alarm Control Panels (FACPs)
  • Comes complete with a conventional photoelectric smoke detector head
  • Steel sampling tube
 
 
D296 Detector humo, haz largo alcance 24V
  • Operates over distances between 30 ft (9 m) and 350 ft (107 m)
  • Six levels of switch-selectable sensitivity
  • Built-in alignment sights and tamper protection
  • Automatic range adjustment, signal synchronization, and contamination adjustment
  • Remote indicator plate annunciates detector status and provides test points for voltage monitoring
 
 
D297 Detector humo, haz largo alcance, 12V
  • Operates over distances between 30 ft (9 m) and 350 ft (107 m)
  • Six levels of switch-selectable sensitivity
  • Built-in alignment sights and tamper protection
  • Automatic range adjustment, signal synchronization, and contamination adjustment
  • Remote indicator plate annunciates detector status and provides test points for voltage monitoring
 
 
D284 Detecto de llama ultravioleta, 24V
  • Highly reliable, long-lasting ultraviolet (UV) receptor tube
  • Low power consumption
  • Can be mixed with other detector types on the control panel's initiation detection circuit (IDC)
  • Easily maintained; can be cleaned without disassembly
 
 
D382 Detector de gas de combustión, 12/24V
  • Alimentación: 12  VCC/VCA o 24 VCC/VCA
  • Sensor semiconductor con sistema de purga automática que no necesita mantenimiento ni recalibración
  • Relé de alarma SPDT (Formato C) y relé de problema SPST (Formato A) diseñados para facilitar la conexión con paneles de control y otros dispositivos
  • Función automática de restauración o bloqueo seleccionable por el instalador
  • Indicadores de estado LED de color verde y rojo
 
 
FCC-380 Detector CO (Macurco CM‑E1)
  • Sensor de estado sólido sin necesidad de mantenimiento
  • Sistema de control con microprocesador que permite un funcionamiento automático virtual
  • Alimentación de 9 VCC a 32 VCC, compatible con sistemas de 12‑V y 24 V
  • Permite una prueba rápida del sensor de CO in situ
  • Indicadores de estado LED con tres colores
  • Tecnología de cuatro cables que permite la conexión de cualquier panel de control con certificación UL
 
 
FIRERAY5000-UL Humo para haz, reflectante
  • Alcance de control ampliado
  • Hasta 2 detectores por controlador del sistema
  • Dos pares de relés de fuego y de fallo (uno por detector)
  • Transmisor y receptor integrados en una sólida carcasa
  • Alineación de LÁSER integral
  • Alineación automática durante el funcionamiento
  • Unidad de control remoto situada al nivel de los ojos para una instalación y programación sencillas
  • Compensación automática para contaminación
  • Unidad de control con pantallas LED y LCD que indican varios estados de funcionamiento
  • Umbrales de alarma ajustables
  • Compensación por desplazamiento de edificios